Salco CS-2000 ANNUNCIATOR SYSTEM FEATURES

The Salco Door Monitor / Annunciator System CS-2000 monitors and displays the real time status of up to 80 doors. The system comprises up to 10 eight zone plug-in modules which monitor and display the status of 8 doors each. The modules are inserted into a standard 19" rack enclosure. An additional control module comprises a system reset switch and a keyswitch to enable or disable the bypass function. The reset switch is also depressed for several seconds to test all the LED indicators. Multiples of CS-2000 systems can be configured for monitoring hundreds of doors.
 

Each plug-in module comprises two LED indicators per door, one yellow and one red.

The yellow indicator illuminates when a door is bypassed. The yellow indicator comprises an integral pushbutton switch which enables the user to bypass or unbypass, i.e., arm or disarm a door.

The red indicator illuminates when a door is violated and extinguishes when restored, and displays the real-time status of the door. The red indicator comprises an integral pushbutton switch which enables the user to reset each door individually. The red indicator always displays the real-time status of a door regardless whether or not it has been bypassed.

Manual reset sequence (Acknowledge) Piezo audible sounds on a sensor violation or restoral until manually reset. Violated sensor's dedicated LED indicator  illuminates flashing on a sensor violation or restoral until manually reset. After being reset the LED indicator  displays the real time true status of the sensor. Audible sounds until acknowledged on a violation or restoral.
 
Automatic reset sequence Piezo audible sounds for 5 seconds on a sensor violation and restoral. The dedicated indicator  for the violated sensor illuminates and remains illuminated as long as the sensor is violated. The LED indicators always displays the real time true status of all sensors.
Choice of either Manual or Automatic Reset Choice of either Manual or Automatic Reset sequence of operation made via field programmable DIP switch on each module.
Entry alert Entry Alert activates the audible sound for 5 seconds when in the manual sequence mode of operation regardless of the duration of the violation.
Selectively delete (bypass) sensors Selectively delete (bypass) sensors from the system causing the deleted sensor's yellow indicator to illuminate. Deleted sensors will cause no alarm on a violation but the violated sensor's dedicated LED red indicator displays the real time true status of the sensor. The 80 yellow indicators have integral pushbuttons for the bypass function.
Keyswitch Keyswitch enables or disables the delete (bypass) sensor function for authorized personnel.
Master output relay Master Output Relay common to all sensors transfers (activates) on alarm and on a power failure.
Auxiliary relay 1 Auxiliary Relay 1 transfers (activates) and remains activated as long as any of the sensors is deleted (bypassed).
 
Auxiliary relay 2 Auxiliary Relay 2 transfers (activates) whenever entry-alert sounds for 5 seconds on violations in the manual or automatic sequence mode of operation.
Memory active when in the automatic reset sequence of operation. Memory active when in the automatic reset sequence of operation. Trace the sequential order of multiple alarms.
Memory history Memory History enables the retrieval of sensors which caused an alarm during the previous memory cycle.
Test all LED indicators Test all LED indicators by depressing the System Reset pushbutton.          